Features
• Four isolated CAN channels
• H13111 CAN bus controller with high-speed ADM3053 CAN transceiver
• 1000V isolation, channel-to-channel and channel-to-host
• ISO 11898 compliance for Part A (11-bit) and Part B extended (29-bit) arbitration IDs
• CAN 2.0A/B protocol with programmable bit rate up to 1Mbit/sec. ISO 11898-5 compliant
• Configurable to support ARINC 825 and CANaerospace Standards
• Standard, Extended and Remote frames supported
• 8 maskable identifier filters
• Filtering on ID and first two data bytes for both Standard and Extended Identifiers
• Monitor (Listen-only) mode
• 8-message Transmit and Receive FIFOs
• Internal 16-bit free running counter for time tagging of transmitted or received messages
• Re-transmission disable capability
Ports et interfaces
Externe I/O
CAN Bus
Depending on the carrier board
Quad-channel isolated CAN bus interface module
controller
Holt H13111 CAN controller with ADM3053 transceiver.
Spécifications mécaniques
Dimensions
70.0mm (L) x 30.0mm (W)
Bus Type
PCIe
Type Mezzanine
IndustryPack
Spécification environnementale
température de stockage
-55°C/+125°C
température de fonctionnement
-40°C/+71°C
humidité relative
5% to 95% non-condensing
Certificats
normes
Operating Vibration
Designed to comply with IEC 60068-2-64: 10-500Hz, 5G-rms, 2 hours/axis.
Operating Shock
Designed to comply with IEC 60068-2-27: 30G, 11ms half sine, 50G, 3mS half sine, 18 shocks at 6 orientations for both test levels.
EMC Directive
Conforms to EMC Directive 2004/108/EC